aASD-120 2.0 Features at a Glance
- 120 amp total load
- Six 20 amp, 120 volt circuits, each with a status indicator
- Oversized buss bars
- Four buss design accommodates 120V or 240V single phase, or 208V three phase power
- Six widely spaced duplex outlets on rear panel
- Outlets can be powered up and down in sequence
- Three position switch allows each circuit to be part of the power sequencing, or to be switched on/off independently
- Sequence timing can be initiated from unit or remotely, using low voltage control wires
- Sequence control signals are available on rear panel to drive additional ASD-120 2.0s or other devices and circuits
- Front panel key switch for security
- Compact two rack space package
- Most economical product of its type
ASD-120 2.0 Specifications
- General
-
- Line Voltage120 (Volts)
- Dimensions3.5” H x 19” W x 10” D (8.9 x 48.3 x 25.4 cm)
- Weight16 lbs
- Other Specifications
-
-
AC Input Voltage:240V single phase or 208V three phase
- Input Current:120 amps maximum
- Output: Six 120V 20A circuits
- Maximum AC Current Rating: Six 120V 20A circuits for 120A total
- Cable Clamp:145R - 1 1/2 inch NM Clamp Type - Wire Size: 2 to 6AWG
- AC Output Receptacles
- Rear Panel Outlets: 6 duplex NEMA 5-20R sequenced.
- Front Panel: 6 thermal circuit breakers, one per duplex pair.
- Operating Temperature and Humidity: 5 to 40C (40 to 105F), <90% Relative Humidity
- User Interface (Front Panel)
- Key-switch: Front panel, 3 position (On/Off/Remote)
- Keys: Included, 1 pair
- Push Button Switch: Front panel
- Circuit Breakers: Front panel, push-button; 6, 20A Thermal Breakers
- Output Circuit Status: Front panel indicators – one per output
- Configuration Switches: Front panel, hidden by security cover;
- Delay Switches: 3 maximum delay switches – 1, 2, and 4 minute
- Switching Modes: Force Off NO/NC
- 12V mode On/Off
- GND mode On/Off
- Momentary/Maintained mode selection
- Fine Delay Adjustment: Potentiometer hidden by security cover.
- Programmable Delay: 7 minutes delay per step
- 35 minutes total delay time
- Control/Status/Triggering(Rear Panel)
- Remote Terminal: Phoenix-style 4 Pin Connector with Screw Terminals;
- +12V @ 250mA, STAT, REM, GND (Class 2 wiring)
- +5 to 30VDC at REM terminal.
- Delay Outputs: Phoenix-style 8-Pin Connector with Screw Terminals
- 6 relay contacts with NO and NC common connections
- Class 2 wiring)
- A, B, C, D, E, and F delay contacts switched with output circuits
- Force Off: Phoenix-style 2 Pin Connector with Screw Terminals;
- Optically isolated, 12V, 10mA current source (Class 2 wiring)
- Senses external relay contact closure
- Power Consumption
- Standby: 5 Watts
- Sequenced ON:20 Watts
- Safety Agencies
- Intertek
- FCC
- RoHS Compliant
-